  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 93
177
Exercises
Disassembly
and Power
4
6. Remove both leads from the wall outlet.
7. Insert the meter’s black lead into the smaller flat (hot) AC outlet plug.
8. Insert the meter’s red lead into the larger flat (neutral) AC outlet plug. The meter reading
should be around 120 volts. Use Table 4.9 to record the reading.
9. Plug the computer power cord into the AC wall outlet that was checked using Steps 3
through 8.
10. Verify the other end of the power cord is not plugged into the computer.
11. Perform the same checks you performed in Steps 3 through 8, except this time check the
power cord end that plugs into the computer. Use Table 4.10 to record the reading.
Table 4.10 Power cord AC checks
Connections Expected voltage Actual voltage
GND to hot 120VAC
GND to neutral 0VAC
Hot to neutral 120VAC
12. If the voltage through the power cord is correct, power off the meter. Notify the instructor
of any incorrect voltages.
Instructor initials: _____________
Lab 4.9 Device DC Voltage Check
Objective: To check the power supply voltages sent to various devices
Parts: Multimeter
Computer
Procedure: Complete the following procedure and perform the accompanying activities.
1. Set the multimeter to DC VOLTAGE (refer to the meter’s manual if unsure about the
setting).
2. Power on the multimeter.
3. Power off the computer.
4. Remove the computer case.
5. Locate a Molex or Berg power connector. If one is not available, disconnect a power con-
nector from a device.
6. Power on the computer.
7. Check the +5 volt DC output from the power supply by placing the meter’s black lead
in (if the connector is a Molex) or on (if the connector is a Berg) one of the grounds* (a
black wire). Place the meter’s red lead on the +5 volt wire (normally a red wire) in or on
the connector. Consult Figure 4.39 for the layout of the Molex and Berg power supply
connections. Figure 4.39 also contains a table with the acceptable voltage levels.
* Use and check both ground connections (black wires going into the connector); do not
check all the voltages using only one ground connection.